Walsc AAC Panel System

    Facade Wall System

    AAC facade system for commercial and high-rise facades.

    Facade Wall System
    Highlights

    Non-combustible facade for high-rise

    75 mm AAC facade system - tested FRL -/120/120, system R up to 3.96 m²K/W (summer). CodeMark certified for NCC Class 2-6.

    Non-combustible core

    AAC passes fire envelope requirements. Weatherproofing tested NATA per BCA FV1 (+5.5 / -7.0 kPa ULS).

    Fast envelope close-up

    Large 600 mm wide panels reduce crane lifts and dry-in time vs panelised brick.

    System Overview

    Commercial Facade System

    Commercial high-rise facades

    Commercial Facade System
    Components

    System components

    Specification (Standard Stocking Size)
    Lengths are various, please contact supplier for more details
    Walsc AAC Panel 75mm Commercial
    Projects

    Trusted in projects across Australia

    Chatswood Commercial Tower

    Chatswood Commercial Tower

    Chatswood, NSW - 2024

    A 20-storey commercial tower using 75mm Commercial AAC Panels as the primary facade system, meeting stringent wind load and fire safety requirements for Class 5 buildings.

    • FRL 240/240/240 facade fire rating
    • High-density 600 kg/m³ panels
    • Wind load rated for 20+ storeys
    • NCC Volume 1 Class 5 compliant
    Rhodes Apartment Complex

    Rhodes Apartment Complex

    Rhodes, NSW - 2023

    A 15-storey Class 2 apartment building with 75mm Commercial AAC Panels for internal shaft walls and service corridors, providing maximum fire separation between units.

    • Internal shaft wall fire separation
    • Rw+Ctr 38dB acoustic rating
    • Service corridor fire-rated walls
    • 120 shaft wall panels installed
    Technical Data

    Material Properties

    Panel Thickness75 mm
    Panel Width600 mm
    Panel LengthCheck with distributor
    Panel Edge ProfileSquare Edge
    Dry Density525 kg/m³
    Ambient Density600 kg/m³
    Density for Design650 kg/m³
    Panel Weight per SQM50 kg/m²
    Characteristic AAC Compressive Strength2.9 MPa
    Reinforcement Tensile Yield Stress500 MPa
    Reinforcement Characteristic Weld Strength3.1 kN
    Ultimate Strength Bending Capacity0.7 kNm/m
    Thermal ResistanceR 0.52
    Coefficient of Thermal Expansion7.0 × 10⁻⁶/K

    Source: Walsc Design & Installation Guide. Values are indicative - confirm with Walsc for project-specific design.

    Have a Question?

    Whether you need a quote, technical advice, or project support - our team is ready to help. Fill in the form and we'll respond within 1 business day.

    Hours

    Mon - Fri, 8am - 5pm AEST