    75mm AAC intertenancy wall for high-performance separation.

    Intertenancy Wall System 75
    Highlights

    Acoustic + Fire for party walls

    75 mm AAC Light intertenancy system - FRL 90/90/90 and Rw+Ctr up to 52 dB, CodeMark certified.

    Acoustic separation

    Rw 63 / Rw+Ctr 52 dB on WIW 7502 discontinuous 90 mm stud. Exceeds NCC Rw+Ctr≥50.

    Fire-rated core

    CSIRO FCO-3092B assessed FRL 90/90/90 across all four WIW 75 system variants.

    System Overview

    75mm Intertenancy Wall System

    Apartment party walls

    75mm Intertenancy Wall System
    Components

    System components

    Specification (Standard Stocking Size)Est. Weight
    Walsc AAC Panel 2400x600x75mm XL, 10/Pack60kg
    Walsc AAC Panel 2550x600x75mm XL, 10/Pack63.5kg
    Walsc AAC Panel 2700x600x75mm XL, 10/Pack67.5kg
    Walsc AAC Panel 2850x600x75mm XL, 10/Pack71kg
    Walsc AAC Panel 3000x600x75mm XL, 10/Pack75kg
    Walsc AAC Panel 3300x600x75mm XL, 10/Pack82.5kg
    Walsc AAC Panel 75mm Light (XL)
    Projects

    Trusted in projects across Australia

    Chatswood Commercial Tower

    Chatswood Commercial Tower

    Chatswood, NSW - 2024

    A 20-storey commercial tower using 75mm Commercial AAC Panels as the primary facade system, meeting stringent wind load and fire safety requirements for Class 5 buildings.

    • FRL 240/240/240 facade fire rating
    • High-density 600 kg/m³ panels
    • Wind load rated for 20+ storeys
    • NCC Volume 1 Class 5 compliant
    Rhodes Apartment Complex

    Rhodes Apartment Complex

    Rhodes, NSW - 2023

    A 15-storey Class 2 apartment building with 75mm Commercial AAC Panels for internal shaft walls and service corridors, providing maximum fire separation between units.

    • Internal shaft wall fire separation
    • Rw+Ctr 38dB acoustic rating
    • Service corridor fire-rated walls
    • 120 shaft wall panels installed
    Technical Data

    Material Properties

    Panel Thickness75 mm
    Panel Width600 mm
    Panel LengthUp to 3300 mm
    Panel Edge ProfileSquare Edge
    Dry Density450 kg/m³
    Density for Design525 kg/m³
    Panel Weight per SQM42 kg/m²
    Reinforcement Tensile Yield Stress500 MPa
    Reinforcement Characteristic Weld Strength3.1 kN
    Ultimate Strength Bending Capacity1.0 kNm/m
    Thermal ResistanceR 0.584

    Source: Walsc Design & Installation Guide. Values are indicative - confirm with Walsc for project-specific design.